Welcome your employees back to work safely. Your environment at work begins with the air your employees breathe.
JADE SCA5000C
Technical Specifications
General Description and Features
Manufacturer: Surgically Clean Air Inc.
Model Name: JADE
Model Number: SCA5000C
Colours Available: Powder Coated Metal Housing – White or Matte Black
Airflow up to 406 CFM / 690 m3/h Hands free touchless control.
Lockable Control Panel to prevent setting changes.
Energy-optimized for operation through special design for high efficiency and with favourable acoustic behavior.
Single point power connection
Ready for operation with minimal setup. Wall mountable accessory available.
Electrical Data
Rated voltage 1~ 120V; 60 Hz, 1.1A
Power Cord: 18AWG*3C, 105°C, VW-1, length 1.83m-3.05m
Avg. Typical Measured Operating Values (By Electrical Meter) @120V Input
Specifications Release Date: January, 2021 Geographical: North American | Series: B/C/D/E
Internal Technologies Included
• Permanent Pre-Filter: Cleanable Fine Mesh
• Ultrafine Aerosol Particulate Filter: HEPA-Rx
• Activated Carbon: Broad spectrum adsorption Coconut Shell Activated Carbon Filter
• Germicidal UV-C+: Non-Ozone Producing 254 nm Doped Quartz Glass Germicidal UV-C
• Hydroxyl Radical Reactivity Chamber: Photocatalytic TiO2 (Titanium Dioxide) mixed phase anatase and rutile.
• Revitalizing Negative ION Chamber: 3,000,000 ions/cm3 Negative Ion Generator
Performance Data
Airflow Cubic Feet Per Minute (CFM)
Airflow Cubic Feet Per Hour (CFH)
Low Medium High Turbo
153 230 312 406
Low Medium High Turbo
9,180 13,800 18,720 24,360
Sound Level
Speed
Low Medium High Turbo
Warranty
Current (Amp)
0.16 0.23 0.33 0.45
Wattage (W)
19.2 27.6 39.6 54
Low Medium High Turbo
<40 dB(A) 43 dB(A) 48 dB(A) 55 dB(A)
Product Safety Data
Surgically Clean Air will either repair or replace any defective or malfunctioning unit at no cost to the client for a 1-year period.
Filtration & Containment Testing
Minimum Inert Material Capture (Fractional Collection Efficiency):
- IEST-RP-CC007.3 Standard 99.998%-99.999% Efficiency at 0.1μm – 0.2μm @230cfm
- EN1822 Standard Minimum 99% Efficiency at 0.0025μm @300cfm
UL/CSA Recognized ETL Product Safety Tested & Certified
Federal ARB Ozone Emissions Tested & Certified: Maximum 0.001ppm ozone as per UL 867- ozone chamber testing and peak ozone test for electronic devices.
Minimum Biological Capture Testing Requirements (Fractional Collection Efficiency)
• (Virus) MS-2 phage (ATCC 15597-B1) – 99.996% efficiency @300 cfm
• (Bacteria) Staph Aureus (ATCC 6538) – 99.998% efficiency @300cfm
• (Fungus) Aspergillus Niger (ATCC 1004) – 99.999% efficiency @300cfm