ATTENTION: PLACE YOUR ORDER TODAY – ESTIMATED DELIVERY IN 5-7 DAYS.
The Philips HeartStart line of AEDs are designed to provide life-saving defibrillation of the heart during a sudden cardiac arrest. Choose either the new HeartStart Onsite AED or the traditional HeartStart FRx AED.
Real-time, step-by-step voice commands paced to your actions, and an audible metronome and CPR guidance assist the responder.
HeartStart includes features to help guide the treatment of sudden cardiac arrest with easy setup, clear voice commands and a real time metronome for performing CPR. HeartStart AEDs conduct a series of automatic self-tests daily, weekly and monthly, including testing the pads, internal circuitry, waveform delivery and battery capacity so you can be assured when the moment comes, you will have a partner by your side.
The HeartStart AEDs are available with options to treat both adults and children with either pediatric SMART pads (optional) or a Pediatric Key (included in the FRx).
Both HeartStart models contain start-of-the-art technology designed to provide life-saving defibrillation shocks to an individual experiencing sudden cardiac arrest. The HeartStart AEDs, are easy to use and feature voice guidance that helps the responder operate the AED as well as CPR guidance using a timed metronome indicator. The HeartStart SMART pads provide feedback to the AED Machine allowing it to adapt its instruction to the responders activity and pace.
1
![]() HeartStart FRx AED with Case × 1Edit options -
+
|
$2,099.00 |
Subtotal | $2,099.00 |
---|---|
Rebate | $0.00 |
Shipping | Free |
Tax | $162.67 |
Total | $2,261.67 |
Onsite | Model: M5066A Option R01:
MODEL NAME: Onsite
MODEL NUMBER: M5066A-R01
DIMENSIONS: 7 cm x 19 cm x 21 cm (2.8˝ x 7.4˝ x 8.3˝) D x H x W
WEIGHT: 1.5 kg (3.3 lbs)
OPERATING TEMPERATURE: 0° – 50° C (32° – 122° F)
ALTITUDE: 0 to 15,000 feet
SHOCK ABUSE: Withstands one-meter drop to any edge, corner or surface
VIBRATION: Meets EN1789 random and swept sine, road ambulance specification in operating and standby states
CAPACITY: Minimum 200 shocks or 4 hours of operating time (EN 60601-2-4:2003)
Onsite | Model: M5066A Option R01:
MODEL NAME: Onsite
MODEL NUMBER: M5066A-R01
DIMENSIONS: 6 cm x 18 cm x 22 cm (2.4˝ x 7.1˝ x 8.9˝) D x H x W
WEIGHT: 1.6 kg (3.5 lbs)
OPERATING TEMPERATURE: Operating/Standby: 32° – 122° F (0° – 50° C) Transient operating (for 20 minutes or less, after rapid transition from 68° F [20° C]): -4° to 122° F (-20 to 50° C); under non-condensing humidity conditions.
ALTITUDE: -400 m to 4,572 m (-1312 ft to 15,000 ft)
SHOCK ABUSE: Withstands 1.22 m (4 ft) drop on any edge, corner, or face of the device onto masonry surface.
CRUSH: 500 kg (1100 lbs)
VIBRATION: Operating: meets MILSTD 810G Fig. 5146E-1, random. Standby: meets MILSTD 810G Fig. 5146E-2, swept sine (helicopter).
CAPACITY: Minimum 200 shocks or 4 hours of operating time (EN 60601-2-4:2003)
The Heartstart Onsite AED is the perfect choice for most businesses, schools, churches, office buildings, and homes. It’s easy to use, includes SMART pads that send feedback to the AED unit during a rescue event and is ideal for most applications.
The Heartstart FRx AED is one of the most adopted AEDs in the World. With over 500,000 units in service world-wide, it has literally set the standard for AEDs. The FRx is tried-and-true and easy to use. The FRx is also rugged, dust proof, and water resistant.
AEDs in churches where hundreds of worshipers congregate every week save countless lives each year.
AEDs on public transportation provide a community service and the opportunity to save the lives of everyday travelers on their way to school, work or everyday travel.
“I don’t remember anything between the time I toweled off in the locker room and when I woke up in a hospital bed 24 hours later.” Joe continues, “When the cardiologist came in and explained that I had suffered Sudden Cardiac Arrest (SCA) due to a plaque rupture in one of my arteries, I was shocked. I never imagined I’d be a candidate for something like this. Then he told me that I was one of the few who survive with virtually no heart or brain damage. At that point, I realized how fortunate I was to have had the Philips ERT team and AED by my side that day.”